1. Switch Off the Machine

  • Turn off the power.
  • Disconnect the power supply for safety.

2. Open the Clamps

  • Release the side clamps holding the sieve frame.
  • Carefully lift the top cover and screen deck.

3. Remove the Old Gasket

  • Take out the worn or damaged rubber gasket from its groove.
  • Clean the gasket seat properly using dry cloth.

4. Clean the Gasket Groove

  • Ensure there is no powder, dust, or residue.
  • A clean seat ensures airtight sealing and prevents leakage.

5. Install the New Gasket

  • Place the new food-grade rubber/silicone gasket into the groove.
  • Press gently all around so it sits even and aligned.
  • Make sure there is no twist or gap.

6. Reassemble the Sifter

  • Put the screen frame and cover back in position.
  • Close and tighten the clamps uniformly.

7. Test Run

  • Switch on the machine.
  • Check for vibrations, leakages, or abnormal sound.
  • If leakage continues, re-adjust the gasket and tighten clamps evenly.

Key Tips

  • Always use food-grade silicone or EPDM gasket.
  • Replace gasket if it shows cracks, hardness, cuts, or deformation.
  • Do not overtighten clamps—this may damage the gasket.
  • Keep extra gaskets in stock for quick maintenance.